Show simple item record

dc.contributor.authorMorenas Aguilar, María D.
dc.contributor.authorRodríguez Perea, Angela
dc.contributor.authorChirosa Ríos, Luis J.
dc.contributor.authorJerez Mayorga, Daniel
dc.contributor.authorVila Suárez, María Elena 
dc.contributor.authorAvalos Solitario, Aldo B.
dc.contributor.authorSoto García, Diego
dc.date.accessioned2024-06-04T11:09:12Z
dc.date.available2024-06-04T11:09:12Z
dc.date.issued2024-04
dc.identifier.citationJournal Of Sports Medicine And Physical Fitness, 64(4), 355-362 (2024)spa
dc.identifier.issn18271928
dc.identifier.urihttp://hdl.handle.net/11093/6930
dc.description.abstractBACKGROUND: A greater motivation for coaches to be more involved in assessment could be the development of specific strength tests closer to specific handball tasks. Therefore, the aims were to determine the reliability of a handball specific strength test battery in young handball players using a functional electromechanical dynamometer (FEMD) and to evaluate the association between the strength test battery and per- formance measurements. METHODS: Thirty-two young handball players (25% males and 75% females) performed a repeated-measurement design over four weeks. The players conducted one session per week, with each measurement consisting of two isometric tests to obtain isometric peak force, and four incremental tests. Moreover, performance handball tests (sprint and throwing velocity [TV]) were recorded. RESULTS: The reliability of the whole handball specific strength tests was very high for the peak and mean strength (ICC=0.70-0.85; CV=8.49- 13.99; SEM=0.44-0.67 kg). The step forward had a moderate association with 5 to 10 meters’ time. The highest correlation between TVmean was found with the peak strength of standing lift and between TVpeak with peak strength of unilateral throw. The sprint total time could be explained by Body Mass Index and peak strength of the standing lift in the 40% and the TVpeak could be explained by arm span and mean strength of the standing lift in the 68%. CONCLUSIONS: The high reliability for all exercises and the significant correlation with handball performance (sprint time and TV) allow us to include these tests in handball team evaluation and trainingen
dc.language.isoengspa
dc.publisherJournal Of Sports Medicine And Physical Fitnessspa
dc.rights© 2023 EDIZIONI MINERVA MEDICA
dc.titleReliability of a handball specific strength test battery and the association with sprint and throwing performance in young handball playersen
dc.typearticlespa
dc.rights.accessRightsembargoedAccessspa
dc.identifier.doi10.23736/S0022-4707.23.15530-7
dc.identifier.editorhttps://www.minervamedica.it/index2.php?show=R40Y9999N00A23122103spa
dc.publisher.departamentoDidácticas especiaisspa
dc.publisher.grupoinvestigacionHealthyFitspa
dc.subject.unesco2411.06 Fisiología del Ejerciciospa
dc.date.updated2024-04-04T15:53:37Z
dc.computerCitationpub_title=Journal Of Sports Medicine And Physical Fitness|volume=64|journal_number=4|start_pag=355|end_pag=362spa


Files in this item

[PDF]

    Show simple item record