Show simple item record

dc.contributor.authorOrtega Veiga, Ignacio 
dc.contributor.authorSieres Atienza, Jaime 
dc.contributor.authorCerdeira Pérez, Fernando 
dc.contributor.authorÁlvarez da Costa, Estrella 
dc.contributor.authorSantos Navarro, José Manuel 
dc.date.accessioned2024-10-15T10:19:34Z
dc.date.available2024-10-15T10:19:34Z
dc.date.issued2024-03-05
dc.identifier.citationScience and Technology for the Built Environment, 30(6): 611-625 (2024)spa
dc.identifier.issn23744731
dc.identifier.issn2374474X
dc.identifier.urihttp://hdl.handle.net/11093/7659
dc.description.abstractCurrent energy efficiency regulations have led to the development of heat pumps equipped with variable speed compressors (VSC) and electronic expansion valves (EEV). To reduce the amount of refrigerant charge, heat pump manufacturers are developing units without a liquid receiver. As a result, the amount of refrigerant charge has a direct impact on the unit performance and needs to be optimized. Previous studies have shown the existence of an optimum refrigerant charge that maximizes the COP at a given operating condition. However, with VSC it is not clear if the optimum charge at a given compressor speed is the adequate one at other speed values. This paper analyzes the effects of the refrigerant charge amount on the performance of a brine-to-water heat pump equipped with a VSC and an EEV. For a given compressor speed, the variation of the COP with the charge showed similar trends and an optimum refrigerant charge could be identified. The charge for the maximum COP changes slightly with the compressor speed. The seasonal coefficient of performance (SCOP) is proposed as a better metric for evaluating the optimum charge. Results show that the SCOP is quite stable with the refrigerant chargeen
dc.description.sponsorshipAgencia Estatal de Investigación | Ref. TED2021-129982B-I00spa
dc.language.isoengspa
dc.publisherScience and Technology for the Built Environmentspa
dc.relationinfo:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2021-2023/TED2021-129982B-I00/ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.titleResearch on the effect of the refrigerant charge in a variable capacity heat pumpen
dc.typearticlespa
dc.rights.accessRightsopenAccessspa
dc.identifier.doi10.1080/23744731.2024.2312798
dc.identifier.editorhttps://www.tandfonline.com/doi/full/10.1080/23744731.2024.2312798spa
dc.publisher.departamentoEnxeñaría mecánica, máquinas e motores térmicos e fluídosspa
dc.publisher.departamentoEnxeñaría químicaspa
dc.publisher.grupoinvestigacionEnxeñería Química, Térmica e Medioambientalspa
dc.subject.unesco3313 Tecnología E Ingeniería Mecánicasspa
dc.date.updated2024-10-14T07:20:01Z
dc.computerCitationpub_title=Science and Technology for the Built Environment|volume=30|journal_number=6|start_pag=611|end_pag=625spa


Files in this item

[PDF]

    Show simple item record

    Attribution-NonCommercial-NoDerivatives 4.0 International
    Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivatives 4.0 International