Cocurrent vs. countercurrent flow arrangement in the indoor heat exchanger of an air-to-water heat pump
ABSTRACT
Introduction. Air source heat pumps (ASHP) are extensively utilized in residential buildings to cater the cooling, heating, and domestic hot water
requirements. However, their performance tends to decline in colder climates, since as the ambient temperature drops, the heat
output decreases, and the compressor discharge temperature rises. [...]